This control is always needed before the service of machines
and equipment. For 0.5 hours evaluate the work of oils, prevent
their late change and accident.
Means of verification
The crucible 75.100 ml, thermometer 250 °С, device for the
slow controlled heating of the oil to 220 – 235 °С, filter paper.Determine the temperature of the beginning and end of crackling/foaming/boiling oil when it is watered, flash point,
decreasing due to loss of viscosity. An oil stains (“drip sample”,
Figures 1&2) on filter paper after 15 - 20 minutes characterizes
the contamination, washing, dispersing properties, water cut and
overheating of the oil.