Recycled Waste Glass [WG] in Concrete

Authored   by   KIM Ibrahim



Abstract

In this study, WG was used as partial substitution of basalt (coarse aggregate), with 0%,5%,10%,15% ,20%, 25%,30%,35%,40%,45% and 50% ratios by weight of basalt. Some mechanical and other concrete properties have been investigated at both hardened and fresh stages. The investigational results that were taken from the tested specimens illustrated that with WG using as a coarse aggregate occurred a loss in a slump, density, and water absorption. It also resulted in the enhancement of the strengths of concrete [compression and tension] until a 25% ratio of substitution by weight. Test results registered that with WG content increase, the strengths gradually increase up to a given limit, and then beyond which they gradually decrease. The maximum influence reached a 25% substitution ratio. At this percentage, the strengths [tension and compression] increasing were approximately 15 % and 14 % with relating to control concrete [0% WG] respectively.

Keywords: Concrete; Waste glass; Coarse aggregate; Compressive strength

Introduction

Concrete comprises three boss constituents (aggregate, cement, and water). The proportion and type of ingredients change the last item (concrete) properties [1]. The waste disposal problem was caused by non-decomposing waste materials, thus contributing to the environmental crisis [2]. Various manufacturing waste substances as tiles waste aggregates from the destruction of buildings, slag, fly ash, etc., have been attempted as extra material in concrete [3]. For many decades’ efforts had been devoted to using WG in concrete [4-5]. Many investigators studied WG usage in plain concrete [6-21]. Glass has been indispensable to man’s life due to its properties such as flexibility, to take any shape with ease, polished surface, resistance to abrasion, safety, and durability. Utilizing WG in concrete has obtained far more attention in parallel to environmental awareness. While Utilizing WG in concrete as aggregate enhances some of the concrete characteristics, it also negatively influences some others. While the quantity of the WG combined within the concrete, reduces the compressive strength because adherence cannot be completed fully between the WG and paste of cement. Additionally, as the WG content increases, the concrete toughness decreases, because glass fails to absorb water and consequently stops many the relief of energy through the cement hydration [22]. Studies in a WG have concluded an unwelcome reaction between waste glass, in which active silica is being, and cement which possesses a large quantity of alkali oxide, named alkali-silica reaction (ASR), consequently expansion grows to the detriment of the sustainability of the concrete [23,24]. Another study indicates that when the quantity of WG rises, the voids in concrete grow owing to the delicate appearance of the waste glass grains and its lower compactness, so the strength of concrete drops [25]. During utilizing coarse waste glass particles as aggregate, the concrete strength decreases, because waste glass aggregates have considerably bad shape, poor surface properties, and high friability [26]. This investigation tried to explore the WG utilizing impact in concrete.

Materials

Cement

The cement utilized in this research was locally sourced, conforming to the ESS 2421/2005 [27]. The cement mechanical properties were measured by laboratory tests that indicated its reasonableness for concrete works. In this investigation, chemical composition and mechanical properties of cement are exhibited in Table 1 & Table 2.

Mixing water

For mixing, drinking water was used.

Super plasticizers

In concrete mixture, the super plasticizer is viewed as high water reducing tool. The super plasticizer used was from SIKA Company.

Experimental Procedure

Mixture proportioning

In this investigation, two sorts of concrete mixes were created. The first is the control concrete mix consisted of sand (594 kg/m3), basalt (1188 kg/m3), cement (400 kg/m3), and water (200 kg/ m3). The second concrete mixes were produced from WG coarse aggregates of 5%, 10%, 15%, 20%, 25%, 30%, 35%, 40%, 45% and 50% ratios as partial substitution of coarse aggregate and with the equal masses of sand, cement, and water of the control mix. Furthermore, a super plasticizer was utilized per m3 to keep the slump values goes between [6-11] cm. Both of the two concrete mixes types were cured for 28 days. Table 6 shows the concrete mixes proportion.

Casting and curing of test specimens

As listed by B.S.1881:1952 [29], cast, compaction, and curing were fulfilled. Tests were done on fresh concretes to define the slump values. For the compressive strength determination at 28 days, three cubes (15cm length) were cast for every concrete mix, also for indirect tensile strength, three cylinders (30cm length and 15cm diameter) was cast.

Testing of specimens

Slump test: Achieved by BS 12350-2:2009 [30], this test was accomplished on fresh concretes to define the concrete workability.

Dry density: Just before the compression test, for totally concrete mixes, the dry density was calculated as stated by B.S.1881:1952 [29].

Water absorption test: Accomplished by B.S.1881:1952 [29]. The cubes dry weight was estimated after eliminating from molds. Moreover, the cube’s mass was measured after submersing in a water tank for curing 28 days of age. Then for every concrete cube, the water absorption ratio was estimated.

Compressive strength: For each mix, concrete cubes with 15cm length were manufactured and cured in water until test age by ESS 1658 /2006 [31].

Splitting tensile strength: For each mix, concrete cylinders with300 mm height and 150 mm diameter were manufactured and cured in water until test age by ESS 1658 /2006 [31].

Results and Discussions

Slump test

The results of the slump tests are given in Table 6. Figure 2 illustrates the decreasing rates in the slump. The slump values were defined to be 10, 9.6, 9.3,8.9,8.7,8.2,7.9,7.7,7.6,7.3, and 7.1 for specimens manufactured from 0%,5%, 10%,15%, 20% ,25,30%,35%,40%,45%, and 50%WG, respectively. The results illustrate the inclination of the slump to lower as the WG ratio rises. This drop in the slump values can be related to the bad geometry of the WG shape, which results in lesser fluidity of the mixes as well as the decrease of fineness modulus. Despite the drop in the slump values, the WG concrete mixes were considered workable. A study by Olomo Rachael O, et al., [2] also announced that rising the mixing ratio of WG coarse aggregate reduced the slump of the concrete. Eme DB, et al., [1] summarized that using a big proportion of WG has been noted to lower the concrete slump value

Dry density

Table 8 displays the dry densities of WG concrete mixes at 28 days of curing ages. The decreasing ratios in dry densities of specimens made of 5%, 10%, 15%, 20%,25%,30%,35%,40%,45%,and 50% waste glass compared to control concrete[0%WG] are 0.25%, 0.63%,0.96%,1.21%,1.42%,1.88% ,2.26%,2.84%,3.31% and 3.85%, respectively, as presented in Figure 3. The decrease in the dry density of the waste glass concrete mixes can be attributed to the specific gravity of the WG, which is lower than that of the basalt. Similar outcomes were recorded by Canbaz & Topcu [10], which established the conclusion that the concrete unit weight with WG is lesser than that without WG. Despite the reduction in the dry density values of WG concrete mixes, they are yet comparable to the control mixes [0%WG].


Water absorption

Table 9 represents the level of water absorption ratio for all mixes. Figure 4 shows that the rate of water absorption decreased with WG content increasing, and this is maybe because the glass water absorption ratio is almost zero. Same results were stated by Muzamil Liaqat, et al., [3], they verified that the WG concrete water absorption ratio is lesser than of concrete without WG, also reported that with increasing WG coarse aggregate ratio the concrete water absorption ratio decreased. In this research, the lowest value of the water absorption ratio was found at 50% WG content.

Compressive strength

The compressive strength test results of control and recycled glass concrete mixes at age 28 days are summarized in Table 10. Each given value is the average of three measurements. It is evident from Table 10 that the usage of recycled glass waste as a basalt replacement until a 25% replacement ratio rises the compressive strength of the concrete mixes related to the control mixture [0%WG], the increase was [6.72%, 8.77%, 10.23%, 11.46%, 13.65%] respectively. Also, it can be noticed from Figure 5 that as the WG content increases from 25% to 50%, the compressive strength decreased gradually, and The reduction of concrete compressive strength was [about 18%] at 50% ratio related with the control mix. The same results were stated by Olomo Rachael O, et al., [2]. They announced that with increasing waste glass coarse aggregate ratio until 25%, the concrete compressive strength increased then decreased after this value. This result agrees with the obtained results in this investigation.

The calculated indirect tensile strengths at age 28 days are displayed in Table 11. Every value is the mean of three measures. Figure 6 registers that the indirect tensile strength leads to an increment with the rise in the proportion of recycled WG replacement in the concrete mix until a 25% ratio, correlated to the control mix. According to the test results, the 28 days indirect tensile strength values are observed to increase by [9.62%, 10.04%, 11.3%, 12.55%, 14.64%] for replacement ratios of 5%, 10%, 15%, 20%, and 25%, respectively. These outcomes agree with Vikash Agrawal, et al., [32], who revealed that for 5% reused glass substitution, the indirect tensile strength of recycled glass concrete increased by 4% at age 28 days. Likewise, it very well may be seen from Table 11 and Figure 6 that as the WG content increases from 25% to 50%, the indirect tensile strength decreased gradually, and the reduction of concrete indirect tensile strength was about 21% at 50% ratio correlated to the control mix.

conclusion

• Coarse aggregate can be substituted by WG until 25% proportion, without decreasing in compressive and tensile strengths.

• 25% WG replacement indicated an around14% increase in compressive strength.

• 25% waste glass replacement indicated an around15 % increase in tensile strength.

• With growing the substitution proportion of coarse WG, the water absorption ratio decreases.

• The best dose of coarse waste glass substitution is 25%.

• The color of concrete does not change during utilizing coarse WG.

• The density lessened by around 4% during using 50% coarse WG.

• The workability lessened by raising the WG content.

 

For more about Iris Publishers please click on: http://irispublishersgroup.com/submit-manuscript.php

 

To read more about this article - https://irispublishers.com/gjes/fulltext/recycled-waste-glass-wg-in-concrete.ID.000627.php

Indexing List of Iris Publishers: https://medium.com/@irispublishers/what-is-the-indexing-list-of-iris-publishers-4ace353e4eee

Iris publishers google scholar citations: https://scholar.google.co.in/scholar?hl=en&as_sdt=0%2C5&q=irispublishers&btnG=


Comments

Popular posts from this blog

Gully Erosion and Landslides in Southeastern Nigeria: Causes, Consequences and Control Measures

Iris Publishers

Iris Publishers