Global Journal of Engineering Sciences (GJES)
Recycled Waste Glass [WG] in Concrete
Authored by KIM Ibrahim
Abstract
In
this study, WG was used as partial substitution of basalt (coarse aggregate),
with 0%,5%,10%,15% ,20%, 25%,30%,35%,40%,45% and 50% ratios by weight of
basalt. Some mechanical and other concrete properties have been investigated at
both hardened and fresh stages. The investigational results that were taken
from the tested specimens illustrated that with WG using as a coarse aggregate
occurred a loss in a slump, density, and water absorption. It also resulted in
the enhancement of the strengths of concrete [compression and tension] until a
25% ratio of substitution by weight. Test results registered that with WG
content increase, the strengths gradually increase up to a given limit, and
then beyond which they gradually decrease. The maximum influence reached a 25%
substitution ratio. At this percentage, the strengths [tension and compression]
increasing were approximately 15 % and 14 % with relating to control concrete
[0% WG] respectively.
Keywords: Concrete; Waste glass; Coarse
aggregate; Compressive strength
Introduction
Concrete
comprises three boss constituents (aggregate, cement, and water). The
proportion and type of ingredients change the last item (concrete) properties
[1]. The waste disposal problem was caused by non-decomposing waste materials,
thus contributing to the environmental crisis [2]. Various manufacturing waste
substances as tiles waste aggregates from the destruction of buildings, slag,
fly ash, etc., have been attempted as extra material in concrete [3]. For many
decades’ efforts had been devoted to using WG in concrete [4-5]. Many
investigators studied WG usage in plain concrete [6-21]. Glass has been
indispensable to man’s life due to its properties such as flexibility, to take
any shape with ease, polished surface, resistance to abrasion, safety, and
durability. Utilizing WG in concrete has obtained far more attention in
parallel to environmental awareness. While Utilizing WG in concrete as
aggregate enhances some of the concrete characteristics, it also negatively
influences some others. While the quantity of the WG combined within the
concrete, reduces the compressive strength because adherence cannot be
completed fully between the WG and paste of cement. Additionally, as the WG
content increases, the concrete toughness decreases, because glass fails to
absorb water and consequently stops many the relief of energy through the
cement hydration [22]. Studies in a WG have concluded an unwelcome reaction
between waste glass, in which active silica is being, and cement which
possesses a large quantity of alkali oxide, named alkali-silica reaction (ASR),
consequently expansion grows to the detriment of the sustainability of the
concrete [23,24]. Another study indicates that when the quantity of WG rises,
the voids in concrete grow owing to the delicate appearance of the waste glass
grains and its lower compactness, so the strength of concrete drops [25].
During utilizing coarse waste glass particles as aggregate, the concrete
strength decreases, because waste glass aggregates have considerably bad shape,
poor surface properties, and high friability [26]. This investigation tried to
explore the WG utilizing impact in concrete.
Materials
Cement
The
cement utilized in this research was locally sourced, conforming to the ESS
2421/2005 [27]. The cement mechanical properties were measured by laboratory
tests that indicated its reasonableness for concrete works. In this
investigation, chemical composition and mechanical properties of cement are
exhibited in Table 1 & Table 2.
Mixing water
For mixing, drinking water was
used.
Super plasticizers
In concrete mixture, the super
plasticizer is viewed as high water reducing tool. The super plasticizer used
was from SIKA Company.
Experimental Procedure
Mixture proportioning
In this investigation, two
sorts of concrete mixes were created. The first is the control concrete mix
consisted of sand (594 kg/m3), basalt (1188 kg/m3), cement (400 kg/m3), and
water (200 kg/ m3). The second concrete mixes were produced from WG coarse aggregates
of 5%, 10%, 15%, 20%, 25%, 30%, 35%, 40%, 45% and 50% ratios as partial
substitution of coarse aggregate and with the equal masses of sand, cement, and
water of the control mix. Furthermore, a super plasticizer was utilized per m3
to keep the slump values goes between [6-11] cm. Both of the two concrete mixes
types were cured for 28 days. Table 6 shows the concrete mixes proportion.
Casting and curing of test specimens
As listed by B.S.1881:1952
[29], cast, compaction, and curing were fulfilled. Tests were done on fresh
concretes to define the slump values. For the compressive strength
determination at 28 days, three cubes (15cm length) were cast for every
concrete mix, also for indirect tensile strength, three cylinders (30cm length
and 15cm diameter) was cast.
Testing of specimens
Slump
test: Achieved by BS 12350-2:2009 [30], this test was
accomplished on fresh concretes to define the concrete workability.
Dry
density: Just before the compression test, for totally concrete
mixes, the dry density was calculated as stated by B.S.1881:1952 [29].
Water
absorption test: Accomplished by B.S.1881:1952 [29]. The cubes dry weight
was estimated after eliminating from molds. Moreover, the cube’s mass was
measured after submersing in a water tank for curing 28 days of age. Then for
every concrete cube, the water absorption ratio was estimated.
Compressive
strength: For each mix, concrete cubes with 15cm length were
manufactured and cured in water until test age by ESS 1658 /2006 [31].
Splitting
tensile strength: For each mix, concrete cylinders with300 mm height and 150
mm diameter were manufactured and cured in water until test age by ESS 1658
/2006 [31].
Results and Discussions
Slump test
The results of the slump tests
are given in Table 6. Figure 2 illustrates the decreasing rates in the slump.
The slump values were defined to be 10, 9.6, 9.3,8.9,8.7,8.2,7.9,7.7,7.6,7.3,
and 7.1 for specimens manufactured from 0%,5%, 10%,15%, 20%
,25,30%,35%,40%,45%, and 50%WG, respectively. The results illustrate the
inclination of the slump to lower as the WG ratio rises. This drop in the slump
values can be related to the bad geometry of the WG shape, which results in
lesser fluidity of the mixes as well as the decrease of fineness modulus.
Despite the drop in the slump values, the WG concrete mixes were considered
workable. A study by Olomo Rachael O, et al., [2] also announced that rising
the mixing ratio of WG coarse aggregate reduced the slump of the concrete. Eme
DB, et al., [1] summarized that using a big proportion of WG has been noted to
lower the concrete slump value
Dry density
Table 8 displays the dry
densities of WG concrete mixes at 28 days of curing ages. The decreasing ratios
in dry densities of specimens made of 5%, 10%, 15%, 20%,25%,30%,35%,40%,45%,and
50% waste glass compared to control concrete[0%WG] are 0.25%, 0.63%,0.96%,1.21%,1.42%,1.88%
,2.26%,2.84%,3.31% and 3.85%, respectively, as presented in Figure 3. The
decrease in the dry density of the waste glass concrete mixes can be attributed
to the specific gravity of the WG, which is lower than that of the basalt. Similar
outcomes were recorded by Canbaz & Topcu [10], which established the
conclusion that the concrete unit weight with WG is lesser than that without
WG. Despite the reduction in the dry density values of WG concrete mixes, they
are yet comparable to the control mixes [0%WG].
Water absorption
Table 9 represents the level
of water absorption ratio for all mixes. Figure 4 shows that the rate of water
absorption decreased with WG content increasing, and this is maybe because the
glass water absorption ratio is almost zero. Same results were stated by
Muzamil Liaqat, et al., [3], they verified that the WG concrete water
absorption ratio is lesser than of concrete without WG, also reported that with
increasing WG coarse aggregate ratio the concrete water absorption ratio
decreased. In this research, the lowest value of the water absorption ratio was
found at 50% WG content.
Compressive strength
The compressive strength test
results of control and recycled glass concrete mixes at age 28 days are
summarized in Table 10. Each given value is the average of three measurements.
It is evident from Table 10 that the usage of recycled glass waste as a basalt
replacement until a 25% replacement ratio rises the compressive strength of the
concrete mixes related to the control mixture [0%WG], the increase was [6.72%,
8.77%, 10.23%, 11.46%, 13.65%] respectively. Also, it can be noticed from
Figure 5 that as the WG content increases from 25% to 50%, the compressive
strength decreased gradually, and The reduction of concrete compressive
strength was [about 18%] at 50% ratio related with the control mix. The same
results were stated by Olomo Rachael O, et al., [2]. They announced that with
increasing waste glass coarse aggregate ratio until 25%, the concrete
compressive strength increased then decreased after this value. This result
agrees with the obtained results in this investigation.
The
calculated indirect tensile strengths at age 28 days are displayed in Table 11.
Every value is the mean of three measures. Figure 6 registers that the indirect
tensile strength leads to an increment with the rise in the proportion of
recycled WG replacement in the concrete mix until a 25% ratio, correlated to
the control mix. According to the test results, the 28 days indirect tensile
strength values are observed to increase by [9.62%, 10.04%, 11.3%, 12.55%,
14.64%] for replacement ratios of 5%, 10%, 15%, 20%, and 25%, respectively.
These outcomes agree with Vikash Agrawal, et al., [32], who revealed that for
5% reused glass substitution, the indirect tensile strength of recycled glass
concrete increased by 4% at age 28 days. Likewise, it very well may be seen
from Table 11 and Figure 6 that as the WG content increases from 25% to 50%,
the indirect tensile strength decreased gradually, and the reduction of
concrete indirect tensile strength was about 21% at 50% ratio correlated to the
control mix.
conclusion
• Coarse aggregate can be
substituted by WG until 25% proportion, without decreasing in compressive and
tensile strengths.
• 25% WG replacement indicated
an around14% increase in compressive strength.
• 25% waste glass replacement
indicated an around15 % increase in tensile strength.
• With growing the
substitution proportion of coarse WG, the water absorption ratio decreases.
• The best dose of coarse
waste glass substitution is 25%.
• The color of concrete does
not change during utilizing coarse WG.
• The density lessened by
around 4% during using 50% coarse WG.
• The workability lessened by
raising the WG content.
For
more about Iris Publishers
please click on: http://irispublishersgroup.com/submit-manuscript.php
To read more about this article - https://irispublishers.com/gjes/fulltext/recycled-waste-glass-wg-in-concrete.ID.000627.php
Indexing List of Iris Publishers: https://medium.com/@irispublishers/what-is-the-indexing-list-of-iris-publishers-4ace353e4eee
Iris
publishers google scholar citations: https://scholar.google.co.in/scholar?hl=en&as_sdt=0%2C5&q=irispublishers&btnG=

Comments
Post a Comment